单选题A refrigerant with oil in solution has a ().A higher boiling temperature for a given pressure than does a pure refrigerantB lower boiling temperature for a given pressure than does a pure refrigerantC boiling pressure equal to that of a pure refrigeran

题目
单选题
A refrigerant with oil in solution has a ().
A

higher boiling temperature for a given pressure than does a pure refrigerant

B

lower boiling temperature for a given pressure than does a pure refrigerant

C

boiling pressure equal to that of a pure refrigerant at a given pressure

D

boiling point will not be affected by entrained oil

参考答案和解析
正确答案: B
解析: 暂无解析
如果没有搜索结果,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.

A.carbon deposits on the compressor suction valves

B.the evaporator temperature to increase

C.rapid corrosion of the thermal expansion valve

D.no operating problems


正确答案:B

第2题:

The Norwegian Government has tried to ______.

A. encourage the oil companies to discover new oil sources
B. prevent oil companies employing people from northern Norway
C. help the oil companies solve many of their problems
D. keep the oil industry to something near its present size

答案:D
解析:
通过文章第一段容易排除A、B、C项,本题正确答案为D。

第3题:

Moisture is removed from a refrigeration system by

A.bleeding refrigerant from the condenser

B.opening a drain petcock on the oil separator

C.condensing the water in the heat exchanger

D.using a dehydrator cartridge


正确答案:D

第4题:

单选题
The sudden reduction of pressure occurring within the crankcase of a refrigeration compressor during starting causes the ().
A

sudden evaporation of wax crystals in the lubricant

B

sudden evaporation of entrapped air in the lubricant

C

release of refrigerant from the oil/refrigerant mixture

D

release of dissolved lubricant from the refrigerant


正确答案: B
解析: 暂无解析

第5题:

A solution provider has proposed a pSeries solution to a new customer.  The solution is complex with a number of technologies that are new to the customer. They have a tight timeline for implementation.  The solution provider has not been able to get a clear understanding as to how the customer will backup the system.  What would be the most appropriate action to address the risks with this solution?()

  • A、Sell Sysback
  • B、Conduct a SAR
  • C、Sell Supportline
  • D、Provide a project timeline

正确答案:B

第6题:

The requirement to carry an Oil Record Book does not apply to a ship that ______.

A.is not equipped to discharge overboard any oil or oily mixture

B.is on an international voyage to a country that is a party to MARPOL

C.has an International Oil Pollution Prevention Certificate

D.has an oily water separator of sufficient capacity for the oil wastes generated


正确答案:A

第7题:

A section of the building has been having intermittent connectivity problems lately. An action plan and solution has been created. Which of the following steps would an administrator perform NEXT?()

  • A、Document the solution and process.
  • B、Establish the most probable cause.
  • C、Implement and test the solution.
  • D、Identify additional symptoms and problems

正确答案:C

第8题:

Sludge may be formed in the oil in the crankcase of a reciprocating air conditioning compressor as a result of ______.

A.refrigerant bubbles in the lube oil

B.refrigerant reducing the lube oil viscosity

C.oxidation(氧化) of the lube oil from overheating

D.reducing the floc or cloud point of the oil


正确答案:C

第9题:

单选题
A decrease in the flash point of diesel engine lube oil indicates the lube oil has become ().
A

contaminated with sludge

B

contaminated with carbon

C

diluted with fuel oil

D

diluted with water


正确答案: B
解析: 暂无解析

第10题:

单选题
A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().
A

a shortage of refrigerant in the system

B

air in the system

C

an accumulation of liquid refrigerant in the crankcase

D

a shortage of oil in the crankcase