单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A always be wide open when the compressor restartsB continue to operate as if the system were in operationC remain open until evaporator pressure equalizes, then

题目
单选题
When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().
A

always be wide open when the compressor restarts

B

continue to operate as if the system were in operation

C

remain open until evaporator pressure equalizes, then close until the compressor restarts

D

always be completely closed until the compressor restarts

如果没有搜索结果,请直接 联系老师 获取答案。
如果没有搜索结果,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur when the compressor

A.has run continuously for a long period

B.suction pressure is below normal

C.oil level is below normal

D.starts after a long idle period


正确答案:D

第2题:

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.

A.an excess of liquid refrigerant

B.the expansion valve overfeeding

C.a fouled compressor suction strainer

D.the compressor short cycling


正确答案:C

第3题:

If the refrigeration compressor crankcase is sweating, the cause may be due to

A.a shortage of refrigerant

B.the compressor running continuously

C.liquid refrigerant returning to the compressor

D.the compressor short cycling on the high pressure cutout


正确答案:C

第4题:

单选题
Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().
A

overheated compressor bearings

B

excess lube oil viscosity

C

carbon deposits on the compressor piston rings

D

wax crystals forming in the lubricant


正确答案: A
解析: 暂无解析

第5题:

单选题
In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()
A

pressurestat

B

high pressure cutout

C

solenoid valve

D

low pressure cutout switch


正确答案: B
解析: 暂无解析

第6题:

Sweating of the refrigeration system compressor crankcase is caused by_______ .

A.too much superheat

B.insufficient superheat

C.suction pressure too low

D.excessive refrigerant returning to the compressor


正确答案:D

第7题:

单选题
Low compressor head pressure in a refrigeration system can be caused by().
A

insufficient condenser cooling water

B

excessive condenser cooling water

C

air in the refrigeration system

D

excessive refrigerant in the system


正确答案: A
解析: 暂无解析

第8题:

When adding oil to a refrigeration system, precautions must be taken to ensure that

A.the compressor suction pressure is not too high

B.all air is purged from the pump and charging fittings

C.the high pressure cutout switch is held open to prevent accidental starting

D.the condenser is completely shutdown first


正确答案:B

第9题:

单选题
When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().
A

flooding back

B

superheating

C

overflowing

D

recycling


正确答案: C
解析: 暂无解析

第10题:

单选题
When adding oil to a refrigeration system, precautions must be taken to ensure that ().
A

the compressor suction pressure is not too high

B

all air is purged from the pump and charging fittings

C

the high pressure cutout switch is held open to prevent accidental starting

D

the condenser is completely shutdown first


正确答案: A
解析: 暂无解析