where oil or chemical drums are stored
in all battery storage locations
in paint lockers
in all of the above locations
第1题:
A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by ______.
A.one control
B.two controls
C.three controls
D.none of the above
第2题:
If a fixed foam firefighting system on a ship is not of the premix type,a sample of the foam liquid must be tested by ______.
A.a Coast Guard inspection officer
B.the safety man aboard the unit
C.the designated person in charge of the unit
D.the manufacturer or his authorized representative
第3题:
A、emission
B、emit
C、radiation
D、evaporation
第4题:
The most effective way of applying carbon dioxide from a portable extinguisher to a fire is by ______.
A.Forming a cloud cover over the flames
B.Directing the gas at the base of the flames in a slow sweeping motion
C.Discharging the carbon dioxide into the heart of the flames
D.Bouncing the discharge off an adjacent bulkhead just above the burning surface
第5题:
A vessel in ocean service that does not have an approved means of processing oily bilge slops or oily ballast must have ______.
A.a fixed piping system for ballast discharge to a reception facility
B.a discharge outlet for the ballast system on each side of the weather deck
C.one portable adapter for a shore connection to the ballast line
D.All of the above
第6题:
In the event of fire in a machinery space,______.
A.the fixed carbon dioxide system should be used only when all other means of extinguishment have failed
B.the fixed carbon dioxide system should be used immediately,as it is the most efficient means of extinguishment
C.water in any form should not be used as it will spread the fire
D.the space should be opened 5 minutes after flooding CO2 to prevent injury to personnel
第7题:
Before operating a non-oceangoing ship greater than 100 gross tons it must have a fixed piping system to discharge oily mixtures ashore. This system must include______.
A.approved oily-water separating equipment
B.a fixed or portable containment system at the shore connection
C.a spare pump in case the main pump is inoperative
D.at least one outlet accessible from the weather deck
第8题:
Theoretical perfect combustion in a diesel engine yields by-products of_____.
A.aldehydes and carbon dioxide
B.water vapor and carbon monoxide
C.nitrogen and carbon monoxide
D.water vapor and carbon dioxide
第9题:
What could result in an incorrect oxygen concentration reading on the oxygen indicator ________.
A.Exposure to carbon dioxide for no more than 1 minute
B.Exposure to carbon dioxide for more than 10 minutes
C.Exposure to a very low concentration of sulfur dioxide for no more than 2 minutes
D.None of the above
第10题:
______, as the chemical extinguisher agent, should be used for an electric fire.
A.dry chemical or foam
B.foam or soda acid
C.carbon dioxide or foam
D.carbon dioxide or dry chemical