海船船员考试

单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A 10B 7C 4D 1

题目
单选题
Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().
A

10

B

7

C

4

D

1

如果没有搜索结果,请直接 联系老师 获取答案。
如果没有搜索结果,请直接 联系老师 获取答案。
相似问题和答案

第1题:

The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.

A.precipitate(使沉淀) silica (硅石)from solution

B.reduce corrosion in the heating coil

C.prevent clogging and erosion in the coil

D.maintain zero water hardness


正确答案:B

第2题:

A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.

A.excessive purging before lighting off

B.insufficient trail for ignition period

C.a faulty transformer in the ignition circuit

D.insufficient purging before lighting off


正确答案:D

第3题:

The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler()

A.salinity is abnormally

B.high steam demand is too

C.feed-water flow is low

D.water level is abnormally low


答案:D

第4题:

单选题
The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().
A

operating the boiler at less than normal water level

B

installing fins on the firesides of water-tubes

C

increasing the amount of excess air to the burners

D

treating the boiler water with chemical oxygen scavengers


正确答案: B
解析: 暂无解析

第5题:

单选题
The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()
A

will be modulated in proportion

B

will be modulated in proportion and integral

C

will be modulated in proportion and differential

D

will not be modulated at all


正确答案: C
解析: 暂无解析

第6题:

Before the seas get rough, it is a good safety practice to ______.

A.secure loose gear

B.move quickly about the ship

C.increase lighting

D.shutdown auxiliary equipment


正确答案:A

第7题:

单选题
The most common cause of scale formation in an auxiliary boiler is ()
A

concentrations of calcium sulfate in the boiler water

B

fuel oil in the feed water

C

improper treatment of the feed water with calcium sulfate

D

excessive feed water alkalinity


正确答案: C
解析: 暂无解析

第8题:

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.

A.high steam pressure in the boiler

B.abnormally high feed-water temperature

C.abnormally high boiler water temperature

D.steam demand exceeding feed pump capacity


正确答案:B

第9题:

单选题
In the event of a flame failure in an auxiliary water-tube boiler, you must()
A

relight the boiler immediately to prevent loss of steam pressure

B

relight the fire off the brickwork as the bricks are cherry red

C

purge the furnace of any combustible gases before attempting to relight the fire

D

speed up the feed pump to prevent dry firing when the burner flame is reestablished


正确答案: C
解析: 暂无解析

第10题:

单选题
In an auxiliary boiler steam and water system, the highest pressure will be in the ().
A

steam stop valve

B

dry pipe

C

feedwater system

D

generating tubes


正确答案: B
解析: 暂无解析

更多相关问题