CMS专题

单选题A data center includes a Power 750 server running AIX and Linux, and PS700 Blades running AIX. What can the customer use to update AIX and Linux, create and deploy LPARs, and set energy caps for both servers from a single console?()A PowerVM Standard E

题目
单选题
A data center includes a Power 750 server running AIX and Linux, and PS700 Blades running AIX. What can the customer use to update AIX and Linux, create and deploy LPARs, and set energy caps for both servers from a single console?()
A

PowerVM Standard Edition

B

VMControl Standard Edition

C

Hardware Management Console

D

IBM Systems Director Standard Edition

参考答案和解析
正确答案: D
解析: 暂无解析
如果没有搜索结果,请直接 联系老师 获取答案。
相似问题和答案

第1题:

The systems administrator of a large manufacturer has POWER5 and POWER6 servers, each with LPARs running AIX 6.1.  They are running several workloads including SAP, DNS, Oracle, DB2 and WebSphere Application Server, and plan to consolidate onto one POWER7 server.   How can the system administrator determine how much benefit Active Memory Expansion (AME) could provide for the consolidated system?()

  • A、Run amepat now on all of the existing LPARs.
  • B、Run amepat after consolidation on all LPARs.
  • C、Run amepat now on all existing LPARs running on the POWER6 servers.
  • D、Run amepat now on all existing LPARs running database applications.

正确答案:A

第2题:

An administrator is attempting to recover from a power failure in the data center. Which of the following is the BEST way to recover the servers?()

  • A、 Bring up the WINS server, the DNS server, then the web server
  • B、 Bring up the web server, the time clock server, then the DHCP server
  • C、 Bring up the backup tape server, the DNS server, then the web server
  • D、 Bring up the active directory server, the DNS server, then the web server

正确答案:D

第3题:

Company.com has recently received a new p5-570 in the data center and intends to Micro-Partition the server. In which order should installation steps be taken?()

  • A、Connect to the network,power on the server,Micro-Partition the server
  • B、Connect to the HMC,power on the server,Micro-Partition the server,connect to the network
  • C、Power on server,connect to the network,Micro-Partition the server,connect to the HMC
  • D、Power on the server,connect to the HMC,Micro-Partition the server,connect to the network

正确答案:B

第4题:

A customer wants to take advantage of IBM’s Micro-Partitioning capabilities for their new AIX applications.   The pSeries technical specialist should recommend purchasing which of the following?()

  • A、p5 hardware, AIX 5.2, Virtual I/O Server
  • B、POWER4 hardware, AIX 5.3, Virtual I/O Server,
  • C、p5 hardware, AIX 5.3, Advanced POWER Virtualization feature
  • D、POWER4 hardware, AIX 5.2, Advanced POWER Virtualization feature

正确答案:C

第5题:

Companycom is migrating from p670 systems running AIX 5.2 to p5 595 systems running AIX 5.3. They will be changing out only the system units. They will re-use the existing 61D drawers and adapters with the new p5 595 systems. What compatibility issue must be considered?() 

  • A、APV features are not supported for some legacy POWER4 adapters
  • B、APV will require the most current maintenance level for AIX 5.2
  • C、APV features will require that legacy POWER4 adapters be updated with new microcode
  • D、The Virtual IO Server must run AIX 5.3 and the LPARs can run either AIX 5.2 or AIX 5.3

正确答案:A

第6题:

Multiple users are trying to telnet to the AIX server. They are able to ping the server successfully, but are getting the following error message:  telnet: connect: A remote host refused an attempted connect operation   Which of the following could be the cause of this problem?()

  • A、The routing table on the AIX server is incorrect.
  • B、The IP address on the network adapter is incorrect.
  • C、The portmap daemon is not running on the AIX server.
  • D、The inetd daemon is not running on the AIX server.

正确答案:D

第7题:

An SNMP alert has been generated by a server in the main data center.The alert stated that the internal temperature of the server has exceeded the threshold.No other servers in the rack have experienced problems,and no other alerts have come from that server about any other events.Which of the following is the cause of this issue?()

  • A、Rack cooling equipment failure
  • B、Dust collection in the server
  • C、Server processor failure
  • D、Server power supply failure

正确答案:B

第8题:

Which of the following is a compelling reason to deploy IBM Systems Director Active Energy Manager (AEM) in a data center with high energy utilization?()

  • A、Removes the requirement for Intelligent PDUs
  • B、Monitor and balance disk speeds according to utilization needs
  • C、Is a required element for EnergyStar certification of the server/data center
  • D、Monitor and report power and thermal trending to optimize energy consumption

正确答案:D

第9题:

A customer wishes to replace 12 older small UNIX systems.  They are running out of floor space in their data center and any solution must take this into consideration.  Assuming that the applications are supported on all AIX versions, which of the following would best meet the customer’s requirements?()

  • A、A p650 running AIX v5.3
  • B、A p5-550 running AIX v5.3
  • C、A p5-570 running Advanced POWER Virtualization
  • D、Multiple rack-mounted p615s running dynamic LPAR

正确答案:C

第10题:

Company.com has four pSeries servers in their data center and wants to deploy multiple Micro-Partitions.  Which of the following data center servers can be used for this purpose?()

  • A、p5-520 running Virtual I/O Server
  • B、p690 running AIX 5L V5.3
  • C、p5-510 running AIX 5L V5.2
  • D、p5-520 running two dedicated processor partitions

正确答案:A

更多相关问题