IBM(000-102)

单选题A customer is interested in using two Power 550 servers to implement a new two node cluster. The cluster willbe using SAN attached disk for shared storage and will be attached to one IP network. Which of the followingadapter configurations will meet th

题目
单选题
A customer is interested in using two Power 550 servers to implement a new two node cluster. The cluster willbe using SAN attached disk for shared storage and will be attached to one IP network. Which of the followingadapter configurations will meet the customer requirements while reducing single points of failure?()
A

A

B

B

C

C

D

D

参考答案和解析
正确答案: B
解析: 暂无解析
如果没有搜索结果,请直接 联系老师 获取答案。
相似问题和答案

第1题:

A two-node cluster is attached via SAN to shared disk. The customer has requested that one of  the nodes be moved to another room 300 feet away. However, this distance exceeds the length specified by the RS232 specifications.  What solution would resolve the RS232 specification issue with the fewest additional components?()

  • A、 Target mode fiber channel can be used with a SAN solution.
  • B、 The heartbeat could be established by using a disk heartbeat.
  • C、 An RS232 line driver can be used to extend the existing serial connection.
  • D、 The NIM for the serial connection can be altered to compensate for the additional delay caused by the increased distance.

正确答案:B

第2题:

You plan to implement a Hyper-V host cluster. The cluster will contain two servers connected to a Storage Area Network (SAN). You need to recommend a storage location for virtual machine (VM) snapshots. The solution must ensure that the VMs can fail over. Which storage location should you recommend?()

  • A、a domain-based Distributed File System (DFS) namespace
  • B、a network share
  • C、the SAN
  • D、a local hard disk

正确答案:C

第3题:

Two file servers have run out of local disk space. The internal drives are at capacity and the company has traditionally only used local disks for storage. Which of the following is the MOST cost effective solution to add storage to both servers?()

A. Install fiber cards into the servers and add direct attached storage.

B. Install fiber cards into the servers and implement a SAN solution.

C. Attach a USB drive to one of the servers.

D. Add a NAS to the environment


参考答案:D

第4题:

A cluster administrator has been asked to install HACMP on two nodes with the following  hardware:   -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage.  In order to eliminate single points of failure,the administrator should first add which of the following:()   

  • A、 an additional 1GB RAM to each node.
  • B、 Another bootable mirrored disk drive.
  • C、 A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.
  • D、 Nothing,because this is a viable cluster solution with no single points of failure.

正确答案:B

第5题:

A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700.  They would like to upgrade and plan for 40 TB capacity.  The customer needs to move to a more scalable storage system to include all servers.Which of the following would be most appropriate to ask first?()

  • A、What are the plans for Disaster Recovery? 
  • B、What are the plans for data migration? 
  • C、Would iSCSI meet your needs? 
  • D、How much space is available in the current storage systems?

正确答案:B

第6题:

A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()

  • A、One fibre channel switch
  • B、Two fibre channel switches
  • C、Two Ethernet cards
  • D、Nothing

正确答案:B

第7题:

Which two statements about Network Attached Storage are correct?()

  • A、Data is accessed using NFS or CIFS.
  • B、Data is accessed at the block level.
  • C、NAS is referred to as captive storage.
  • D、Storage devices can be shared between users.
  • E、A NAS implementation is not as fast as a DAS implementation.

正确答案:C,D

第8题:

Which two statements about Network Attached Storage are correct?()

A. Data is accessed using NFS or CIFS.

B. Data is accessed at the block level.

C. NAS is referred to as captive storage.

D. Storage devices can be shared between users.

E. A NAS implementation is not as fast as a DAS implementation.


参考答案:C, D

第9题:

A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()

  • A、Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs
  • B、Move the existing physical network and storage adapters to the new system and virtualize the I/O using a  single VIO Server.
  • C、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC  connectors and dual HBAs.
  • D、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC  connectors and the other with dual HBAs.

正确答案:C

第10题:

Company.com is migrating from a third party managed disk subsystem to an IBM TotalStorage Enterprise Storage Server. Connection of the new storage server is complete, and it has been tested on all of the nodes in the three node HACMP cluster.  How does the customer migrate to the new storage server with minimum down time?()

  • A、 Shut down one node at a time and let the other node serve the application
  • B、 Stop HACMP with the forced option and perform migration of the disks on one node,then restart HACMP
  • C、 Stop both nodes and perform the migration all at once using standard AIX commands in parallel, then restart the cluster
  • D、 Use C-SPOC to add the new disks to the cluster and migrate the information off the existing disks, then remove the old disks with C-SPOC

正确答案:D

更多相关问题